Seismic Assessment of a North American Structure to ASCE 7 Standards

22/10/2025

Eadon Consulting were recently requested to support a client with the seismic assessment of a structure intended for a location in North America.  The assessment was performed against ASCE 7 (North American design code), which provides guidance for design loads for structures, including seismic loading.  It provides a method for response spectrum analysis of a structure in an earthquake.   

A finite element analysis (FEA) model with only beam elements was created in STAAD.pro to represent the structure. To ensure an accurate prediction of the dynamic response, particular attention was paid to representing the mass distribution and the overall stiffness of the structure. A modal analysis was performed initially to determine the frequency responses of the structure, with a minimum 90% mass participation in each direction and a 33Hz cutoff frequency.  Since damping is not specified in ASCE 7, a value of 4% was assumed using guidance from ASCE 4.  The modal responses in each direction were combined within the FEA using Complete Quadratic Combination (CQC).  This modal analysis was performed for the two outlying configurations of the structure.

The design basis event (DBE) response spectrum was then derived in accordance with ASCE 7 for the vertical and horizontal directions and applied to the FEA model using a response spectrum analysis.  The load combinations were created in accordance with ASCE 7, taking account of the reversible DBE loading and allowing for the horizontal directions to be considered separately (Seismic Design Category B structure).  An important requirement of ASCE 7 is to ensure that the response spectrum analysis complies with the minimum base shear assessment requirements; in this case the minimum was not achieved, and hence a scaling factor was applied to the results, as per the guidance. 

The results were reviewed to ensure global stability of the structure and also to ensure that all reactions were compliant with the real-world restraint conditions (e.g., feet were modelled as pinned but are designed as compression supports only; results were reviewed to ensure no uplift reactions occurred at the feet). The stresses within the structural members were assessed against AISC 360-22 (North American design code for design of structural steel). 

 

Share This