Home | Projects | Waterways & Marine |
Holland Haven Stop Logs and Flap Gates
Eadon Consulting was commissioned by ECS Engineering to inspect, assess, and recommend improvements for deteriorating stop logs and flap gates at Holland Haven in Essex. This site, where the Holland Brook flows into the North Sea, relies on a flap gate which allows water to flow out when the tide is low but prevents seawater from flooding inland when the tide rises.
Key facts
Over time, exposure to the corrosive saltwater had caused significant damage to the flap gate, making it necessary to remove it for inspection.
Although stop logs had already been designed, they hadn’t been used in years, so Eadon’s initial role was to perform a visual inspection and structural assessment of the tidal side stop logs. During our inspection, we found that the original design of the stop logs was inadequate and that they had suffered significant section loss, making them much weaker than intended. As a result, our scope expanded to include recommendations for repairs and modifications to make them fit for purpose. Following our recommendations, the stop logs were completely refurbished and then deployed at Holland Haven.
The flap gate was removed by crane for inspection and we conducted a visual condition assessment of it. We identified several issues that needed attention, some of which required design changes. The gate was then shot-blasted and we carried out a further, final inspection before it was reinstalled.
The structural assessment of the stop logs and the design work on the flap gate were carried out in accordance with DIN 19704-1, BS EN 1993-1-1 Eurocode 3 and BS EN 1993-1-8 Eurocode 3.